![Caesium standard](https://www.english.nina.az/wikipedia/image/aHR0cHM6Ly91cGxvYWQud2lraW1lZGlhLm9yZy93aWtpcGVkaWEvY29tbW9ucy90aHVtYi80LzQzL05JU1QtRjJfY2VzaXVtX2ZvdW50YWluX2F0b21pY19jbG9jay5qcGcvMTYwMHB4LU5JU1QtRjJfY2VzaXVtX2ZvdW50YWluX2F0b21pY19jbG9jay5qcGc=.jpg )
The caesium standard is a primary frequency standard in which the photon absorption by transitions between the two hyperfine ground states of caesium-133 atoms is used to control the output frequency. The first caesium clock was built by Louis Essen in 1955 at the National Physical Laboratory in the UK and promoted worldwide by Gernot M. R. Winkler of the United States Naval Observatory.
![image](https://www.english.nina.az/wikipedia/image/aHR0cHM6Ly93d3cuZW5nbGlzaC5uaW5hLmF6L3dpa2lwZWRpYS9pbWFnZS9hSFIwY0hNNkx5OTFjR3h2WVdRdWQybHJhVzFsWkdsaExtOXlaeTkzYVd0cGNHVmthV0V2WTI5dGJXOXVjeTkwYUhWdFlpODBMelF6TDA1SlUxUXRSakpmWTJWemFYVnRYMlp2ZFc1MFlXbHVYMkYwYjIxcFkxOWpiRzlqYXk1cWNHY3ZNakl3Y0hndFRrbFRWQzFHTWw5alpYTnBkVzFmWm05MWJuUmhhVzVmWVhSdmJXbGpYMk5zYjJOckxtcHdadz09LmpwZw==.jpg)
Caesium atomic clocks are one of the most accurate time and frequency standards, and serve as the primary standard for the definition of the second in the International System of Units (SI), the modern metric system. By definition, radiation produced by the transition between the two hyperfine ground states of caesium-133 (in the absence of external influences such as the Earth's magnetic field) has a frequency, ΔνCs, of exactly 9192631770 Hz. That value was chosen so that the caesium second equaled, to the limit of measuring ability in 1960 when it was adopted, the existing standard ephemeris second based on the Earth's orbit around the Sun. Because no other measurement involving time had been as precise, the effect of the change was less than the experimental uncertainty of all existing measurements.
While the second is the only base unit to be explicitly defined in terms of the caesium standard, the majority of SI units have definitions that mention either the second, or other units defined using the second. Consequently, every base unit except the mole and every named derived unit except the coulomb, ohm, siemens, gray, sievert, radian, and steradian have values that are implicitly defined by the properties of the caesium-133 hyperfine transition radiation. And of these, all but the mole, the coulomb, and the dimensionless radian and steradian are implicitly defined by the general properties of electromagnetic radiation.
Technical details
The official definition of the second was first given by the BIPM at the 13th General Conference on Weights and Measures in 1967 as: "The second is the duration of 9192631770 periods of the radiation corresponding to the transition between the two hyperfine levels of the ground state of the caesium 133 atom." At its 1997 meeting the BIPM added to the previous definition the following specification: "This definition refers to a caesium atom at rest at a temperature of 0 K."
The BIPM restated this definition in its 26th conference (2018), "The second is defined by taking the fixed numerical value of the caesium frequency ∆Cs, the unperturbed ground-state hyperfine transition frequency of the caesium 133 atom, to be 9 192 631 770 when expressed in the unit Hz, which is equal to s–1."
The meaning of the preceding definition is as follows. The caesium atom has a ground state electron state with configuration [Xe] 6s1 and, consequently, atomic term symbol 2S1/2. This means that there is one unpaired electron and the total electron spin of the atom is 1/2. Moreover, the nucleus of caesium-133 has a nuclear spin equal to 7/2. The simultaneous presence of electron spin and nuclear spin leads, by a mechanism called hyperfine interaction, to a (small) splitting of all energy levels into two sub-levels. One of the sub-levels corresponds to the electron and nuclear spin being parallel (i.e., pointing in the same direction), leading to a total spin F equal to F = 7/2 + 1/2 = 4; the other sub-level corresponds to anti-parallel electron and nuclear spin (i.e., pointing in opposite directions), leading to a total spin F = 7/2 − 1/2 = 3. In the caesium atom it so happens that the sub-level lowest in energy is the one with F = 3, while the F = 4 sub-level lies energetically slightly above. When the atom is irradiated with electromagnetic radiation having an energy corresponding to the energetic difference between the two sub-levels the radiation is absorbed and the atom is excited, going from the F = 3 sub-level to the F = 4 one. After a small fraction of a second the atom will re-emit the radiation and return to its F = 3 ground state. From the definition of the second it follows that the radiation in question has a frequency of exactly 9.19263177 GHz, corresponding to a wavelength of about 3.26 cm and therefore belonging to the microwave range.
Note that a common confusion involves the conversion from angular frequency () to frequency (
), or vice versa. Angular frequencies are conventionally given as s–1 in scientific literature, but here the units implicitly mean radians per second. In contrast, the unit Hz should be interpreted as cycles per second. The conversion formula is
, which implies that 1 Hz corresponds to an angular frequency of approximately 6.28 radians per second (or 6.28 s–1 where radians is omitted for brevity by convention).
Parameters and significance in the second and other SI units
Suppose the caesium standard has the parameters:
- Velocity: c
- Energy/frequency: h
- Time period: ΔtCs
- Frequency: ΔνCs
- Wavelength: ΔλCs
- Photon energy: ΔECs
- Photon mass equivalent: ΔMCs
Time and frequency
The first set of units defined using the caesium standard were those relating to time, with the second being defined in 1967 as "the duration of 9 192 631 770 periods of the radiation corresponding to the transition between the two hyperfine levels of the ground state of the caesium 133 atom" meaning that:
- 1 second, s, = 9,192,631,770 ΔtCs
- 1 hertz, Hz, = 1/s = ΔνCs/9,192,631,770
- 1 becquerel, Bq, = 1 nuclear decay/s = 1/9,192,631,770 nuclear decays/ΔtCs
This also linked the definitions of the derived units relating to force and energy (see below) and of the ampere, whose definition at the time made reference to the newton, to the caesium standard. Before 1967 the SI units of time and frequency were defined using the tropical year and before 1960 by the length of the mean solar day
Length
In 1983, the meter was, indirectly, defined in terms of the caesium standard with the formal definition "The metre is the length of the path travelled by light in vacuum during a time interval of 1/299 792 458 of a second. This implied:
- 1 metre, m, = c s/299,792,458 = 9,192,631,770/299,792,458 c ΔtCs = 9,192,631,770/299,792,458 ΔλCs
- 1 radian, rad, = 1 m/m = ΔλCs/ΔλCs = 1 (dimensionless unit of angle)
- 1 steradian, sr, = 1 m2/m2 = ΔλCs2/ΔλCs2 = 1 (dimensionless unit of solid angle)
Between 1960 and 1983, the metre had been defined by the wavelength of a different transition frequency associated with the krypton-86 atom. This had a much higher frequency and shorter wavelength than the caesium standard, falling inside the visible spectrum. The first definition, used between 1889 and 1960, was by the international prototype meter.
Mass, energy, and force
Following the 2019 revision of the SI, electromagnetic radiation, in general, was explicitly defined to have the exact parameters:
- c = 299,792,458 m/s
- h = 6.62607015×10−34 J s
The caesium-133 hyperfine transition radiation was explicitly defined to have frequency:
- ΔνCs = 9,192,631,770 Hz
Though the above values for c and ΔνCs were already obviously implicit in the definitions of the metre and second. Together they imply:
- ΔtCs = 1/ΔνCs = s/9,192,631,770
- ΔλCs = c ΔtCs = 299,792,458/9,192,631,770 m
- ΔECs = h ΔνCs = 9,192,631,770 Hz × 6.62607015×10−34 J s = 6.09110229711386655×10−24 J
- ΔMCs = ΔECs/c2 = 6.09110229711386655×10−24 J/89,875,517,873,681,764 m2/s2 = 6.09110229711386655/8.9875517873681764×1040 kg
Notably, the wavelength has a fairly human-sized value of about 3.26 centimetres and the photon energy is surprisingly close to the average molecular kinetic energy per degree of freedom per kelvin. From these it follows that:
- 1 kilogram, kg, = 8.9875517873681764×1040/6.09110229711386655 ΔMCs
- 1 joule, J, = 1024/6.09110229711386655 ΔECs
- 1 watt, W, = 1 J/s = 1014/5.59932604907689089550702935 ΔECs ΔνCs
- 1 newton, N, = 1 J/m = 2.99792458×1022/5.59932604907689089550702935 ΔECs/ΔλCs
- 1 pascal, Pa, = 1 N/m2 = 2.6944002417373989539335912×1019/4.73168129737820913189287698892486811451620615 ΔECs/ΔλCs3
- 1 gray, Gy, = 1 J/kg = 1/89,875,517,873,681,764 ΔECs/ΔMCs = c2/89,875,517,873,681,764
- 1 sievert, Sv, = the ionizing radiation dose equivalent to 1 gray of gamma rays
Prior to the revision, between 1889 and 2019, the family of metric (and later SI) units relating to mass, force, and energy were somewhat notoriously defined by the mass of the International Prototype of the Kilogram (IPK), a specific object stored at the headquarters of the International Bureau of Weights and Measures in Paris, meaning that any change to the mass of that object would have resulted in a change to the size of the kilogram and of the many other units whose value at the time depended on that of the kilogram.
Temperature
From 1954 to 2019, the SI temperature scales were defined using the triple point of water and absolute zero. The 2019 revision replaced these with an assigned value for the Boltzmann constant, k, of 1.380649×10−23 J/K, implying:
- 1 kelvin, K, = 1.380649×10−23 J/2 per degree of freedom = 1.380649×10−23 × 1024/2/6.09110229711386655 ΔECs per degree of freedom = 1.380649/1.21822045942277331 ΔECs per degree of freedom
- Temperature in degrees Celsius, °C, = temperature in kelvins - 273.15 = 1.21822045942277331 × kinetic energy per degree of freedom - 377.12427435 ΔECs/1.380649 ΔECs
Amount of substance
The mole is an extremely large number of "elementary entities" (i.e. atoms, molecules, ions, etc). From 1969 to 2019, this number was 0.012 × the mass ratio between the IPK and a carbon 12 atom. The 2019 revision simplified this by assigning the Avogadro constant the exact value 6.02214076×1023 elementary entities per mole, thus, uniquely among the base units, the mole maintained its independence from the caesium standard:
- 1 mole, mol, = 6.02214076×1023 elementary entities
- 1 katal, kat, = 1 mol/s = 6.02214076×1014/9.19263177 elementary entities/ΔtCs
Electromagnetic units
Prior to the revision, the ampere was defined as the current needed to produce a force between 2 parallel wires 1 m apart of 0.2 μN per meter. The 2019 revision replaced this definition by giving the charge on the electron, e, the exact value 1.602176634×10−19 coulombs. Somewhat incongruously, the coulomb is still considered a derived unit and the ampere a base unit, rather than vice versa. In any case, this convention entailed the following exact relationships between the SI electromagnetic units, elementary charge, and the caesium-133 hyperfine transition radiation:
- 1 coulomb, C, = 1019/1.602176634 e
- 1 ampere, or amp, A, = 1 C/s = 109/1.472821982686006218 e ΔνCs
- 1 volt, V, = 1 J/C = 1.602176634×105/6.09110229711386655 ΔECs/e
- 1 farad, F, = 1 C/V = 6.09110229711386655×1014/2.566969966535569956 e2/ΔECs
- 1 ohm, Ω, = 1 V/A = 2.359720966701071721258310212×10−4/6.09110229711386655 ΔECs/ΔνCs e2 = 2.359720966701071721258310212×10−4/6.09110229711386655 h/e2
- 1 siemens, S, = 1/Ω = 6.09110229711386655×104/2.359720966701071721258310212 e2/h
- 1 weber, Wb, = 1 V s = 1.602176634×1015/6.62607015 ΔECs ΔtCs/e = 1.602176634×1015/6.62607015 h/e
- 1 tesla, T, = 1 Wb/m2 = 1.43996454705862285832702376×1012/5.59932604907689089550702935 ΔECs ΔtCs/e ΔλCs2 = 1.43996454705862285832702376×1012/5.59932604907689089550702935 E/e c ΔλCs
- 1 henry, H, = Ω s = 2.359720966701071721258310212×106/6.62607015 h ΔtCs/e2
Optical units
From 1967 to 1979 the SI optical units, lumen, lux, and candela are defined using the Incandescent glow of platinum at its melting point. After 1979, the candela was defined as the luminous intensity of a monochromatic visible light source of frequency 540 THz (i.e 6000/1.02140353 that of the caesium standard) and radiant intensity 1/683 watts per steradian. This linked the definition of the candela to the caesium standard and, until 2019, to the IPK. Unlike the units relating to mass, energy, temperature, amount of substance, and electromagnetism, the optical units were not massively redefined in 2019, though they were indirectly affected since their values depend on that of the watt, and hence of the kilogram. The frequency used to define the optical units has the parameters:
- Frequency: 540 THz
- Time period: 50/27 fs
- Wavelength: 14.9896229/27 μm
- Photon energy: 5.4×1014 Hz × 6.62607015×10−34 J s = 3.578077881×10−19 J
- luminous efficacy, KCD, = 683 lm/W
- Luminous energy per photon,
, = 3.578077881×10−19 J × 683 lm/W = 2.443827192723×10−16 lm s
This implies:
- 1 lumen, lm, = 106/2.246520349221536260971
ΔνCs
- 1 candela, cd, = 1 lm/sr = 106/2.246520349221536260971
ΔνCs/sr
- 1 Lux, lx, = 1 lm/m2 = 8.9875517873681764×102/1.898410313566852566340456048807087002459
ΔνCs/ΔλCs2
Summary
The parameters of the caesium 133 hyperfine transition radiation expressed exactly in SI units are:
- Frequency = 9,192,631,770 Hz
- Time period = 1/9,192,631,770 s
- Wavelength = 299,792,458/9,192,631,770 m
- Photon energy = 6.09110229711386655×10−24 J
- Photon mass equivalent = 6.09110229711386655×10−40/8.9875517873681764 kg
If the seven base units of the SI are expressed explicitly in terms of the SI defining constants, they are:
- 1 second = 9,192,631,770/ΔνCs
- 1 metre = 9,192,631,770/299,792,458 c/ΔνCs
- 1 kilogram = 8.9875517873681764×1040/6.09110229711386655 h ΔνCs/c2
- 1 ampere = 109/1.472821982686006218 e ΔνCs
- 1 kelvin = 13.80649/6.09110229711386655 h ΔνCs/k
- 1 mole = 6.02214076×1023 elementary entities
- 1 candela = 1011/3.82433969151951648163130104605 h ΔνCs2KCD/sr
Ultimately, 6 of the 7 base units notably have values that depend on that of ΔνCs, which appears far more often than any of the other defining constants.
See also
- Rubidium standard
- Nuclear clock
References
- L. Essen, J.V.L. Parry (1955). "An Atomic Standard of Frequency and Time Interval: A Caesium Resonator". Nature. 176 (4476): 280–282. Bibcode:1955Natur.176..280E. doi:10.1038/176280a0. S2CID 4191481.
- Markowitz, W.; Hall, R.; Essen, L.; Parry, J. (1958). "Frequency of Cesium in Terms of Ephemeris Time". Physical Review Letters. 1 (3): 105. Bibcode:1958PhRvL...1..105M. doi:10.1103/PhysRevLett.1.105.
- "Comité international des poids et mesures (CIPM): Proceedings of the Sessions of the 86th Meeting" (PDF) (in French and English). Paris: Bureau International des Poids et Mesures. 23–25 Sep 1997. p. 229. Archived from the original (PDF) on 4 December 2020. Retrieved 30 December 2019.
- "Resolution 1 of the 26th CGPM" (in French and English). Paris: Bureau International des Poids et Mesures. 2018. pp. 472 of the official French publication. Archived from the original on 2021-02-04. Retrieved 2019-12-29.
- "Second – BIPM".
- "Metre - BIPM".
- "Resolution 1 (2018) - BIPM".
- "Kilogram - BIPM".
- "Kelvin - BIPM".
- "Mole - BIPM".
- "Ampere - BIPM".
- "Candela - BIPM".
This article incorporates public domain material from Federal Standard 1037C. General Services Administration. Archived from the original on 2022-01-22. (in support of MIL-STD-188).
External links
![image](https://www.english.nina.az/wikipedia/image/aHR0cHM6Ly93d3cuZW5nbGlzaC5uaW5hLmF6L3dpa2lwZWRpYS9pbWFnZS9hSFIwY0hNNkx5OTFjR3h2WVdRdWQybHJhVzFsWkdsaExtOXlaeTkzYVd0cGNHVmthV0V2Wlc0dmRHaDFiV0l2TkM4MFlTOURiMjF0YjI1ekxXeHZaMjh1YzNabkx6TXdjSGd0UTI5dGJXOXVjeTFzYjJkdkxuTjJaeTV3Ym1jPS5wbmc=.png)
The caesium standard is a primary frequency standard in which the photon absorption by transitions between the two hyperfine ground states of caesium 133 atoms is used to control the output frequency The first caesium clock was built by Louis Essen in 1955 at the National Physical Laboratory in the UK and promoted worldwide by Gernot M R Winkler of the United States Naval Observatory A caesium atomic fountain used as part of an atomic clock Caesium atomic clocks are one of the most accurate time and frequency standards and serve as the primary standard for the definition of the second in the International System of Units SI the modern metric system By definition radiation produced by the transition between the two hyperfine ground states of caesium 133 in the absence of external influences such as the Earth s magnetic field has a frequency DnCs of exactly 9192 631 770 Hz That value was chosen so that the caesium second equaled to the limit of measuring ability in 1960 when it was adopted the existing standard ephemeris second based on the Earth s orbit around the Sun Because no other measurement involving time had been as precise the effect of the change was less than the experimental uncertainty of all existing measurements While the second is the only base unit to be explicitly defined in terms of the caesium standard the majority of SI units have definitions that mention either the second or other units defined using the second Consequently every base unit except the mole and every named derived unit except the coulomb ohm siemens gray sievert radian and steradian have values that are implicitly defined by the properties of the caesium 133 hyperfine transition radiation And of these all but the mole the coulomb and the dimensionless radian and steradian are implicitly defined by the general properties of electromagnetic radiation Technical detailsThe official definition of the second was first given by the BIPM at the 13th General Conference on Weights and Measures in 1967 as The second is the duration of 9192 631 770 periods of the radiation corresponding to the transition between the two hyperfine levels of the ground state of the caesium 133 atom At its 1997 meeting the BIPM added to the previous definition the following specification This definition refers to a caesium atom at rest at a temperature of 0 K The BIPM restated this definition in its 26th conference 2018 The second is defined by taking the fixed numerical value of the caesium frequency Cs the unperturbed ground state hyperfine transition frequency of the caesium 133 atom to be 9 192 631 770 when expressed in the unit Hz which is equal to s 1 The meaning of the preceding definition is as follows The caesium atom has a ground state electron state with configuration Xe 6s1 and consequently atomic term symbol 2S1 2 This means that there is one unpaired electron and the total electron spin of the atom is 1 2 Moreover the nucleus of caesium 133 has a nuclear spin equal to 7 2 The simultaneous presence of electron spin and nuclear spin leads by a mechanism called hyperfine interaction to a small splitting of all energy levels into two sub levels One of the sub levels corresponds to the electron and nuclear spin being parallel i e pointing in the same direction leading to a total spin F equal to F 7 2 1 2 4 the other sub level corresponds to anti parallel electron and nuclear spin i e pointing in opposite directions leading to a total spin F 7 2 1 2 3 In the caesium atom it so happens that the sub level lowest in energy is the one with F 3 while the F 4 sub level lies energetically slightly above When the atom is irradiated with electromagnetic radiation having an energy corresponding to the energetic difference between the two sub levels the radiation is absorbed and the atom is excited going from the F 3 sub level to the F 4 one After a small fraction of a second the atom will re emit the radiation and return to its F 3 ground state From the definition of the second it follows that the radiation in question has a frequency of exactly 9 192631 77 GHz corresponding to a wavelength of about 3 26 cm and therefore belonging to the microwave range Note that a common confusion involves the conversion from angular frequency w displaystyle omega to frequency f displaystyle f or vice versa Angular frequencies are conventionally given as s 1 in scientific literature but here the units implicitly mean radians per second In contrast the unit Hz should be interpreted as cycles per second The conversion formula is w 2pf displaystyle omega 2 pi f which implies that 1 Hz corresponds to an angular frequency of approximately 6 28 radians per second or 6 28 s 1 where radians is omitted for brevity by convention Parameters and significance in the second and other SI unitsSuppose the caesium standard has the parameters Velocity c Energy frequency h Time period DtCs Frequency DnCs Wavelength DlCs Photon energy DECs Photon mass equivalent DMCsTime and frequency The first set of units defined using the caesium standard were those relating to time with the second being defined in 1967 as the duration of 9 192 631 770 periods of the radiation corresponding to the transition between the two hyperfine levels of the ground state of the caesium 133 atom meaning that 1 second s 9 192 631 770 DtCs 1 hertz Hz 1 s DnCs 9 192 631 770 1 becquerel Bq 1 nuclear decay s 1 9 192 631 770 nuclear decays DtCs This also linked the definitions of the derived units relating to force and energy see below and of the ampere whose definition at the time made reference to the newton to the caesium standard Before 1967 the SI units of time and frequency were defined using the tropical year and before 1960 by the length of the mean solar day Length In 1983 the meter was indirectly defined in terms of the caesium standard with the formal definition The metre is the length of the path travelled by light in vacuum during a time interval of 1 299 792 458 of a second This implied 1 metre m c s 299 792 458 9 192 631 770 299 792 458 c DtCs 9 192 631 770 299 792 458 DlCs 1 radian rad 1 m m DlCs DlCs 1 dimensionless unit of angle 1 steradian sr 1 m2 m2 DlCs 2 DlCs 2 1 dimensionless unit of solid angle Between 1960 and 1983 the metre had been defined by the wavelength of a different transition frequency associated with the krypton 86 atom This had a much higher frequency and shorter wavelength than the caesium standard falling inside the visible spectrum The first definition used between 1889 and 1960 was by the international prototype meter Mass energy and force Following the 2019 revision of the SI electromagnetic radiation in general was explicitly defined to have the exact parameters c 299 792 458 m s h 6 626070 15 10 34 J s The caesium 133 hyperfine transition radiation was explicitly defined to have frequency DnCs 9 192 631 770 Hz Though the above values for c and DnCs were already obviously implicit in the definitions of the metre and second Together they imply DtCs 1 DnCs s 9 192 631 770 DlCs c DtCs 299 792 458 9 192 631 770 m DECs h DnCs 9 192 631 770 Hz 6 626070 15 10 34 J s 6 091102 297 113 866 55 10 24 J DMCs DECs c2 6 091102 297 113 866 55 10 24 J 89 875 517 873 681 764 m2 s2 6 091102 297 113 866 55 8 987551 787 368 1764 1040 kg Notably the wavelength has a fairly human sized value of about 3 26 centimetres and the photon energy is surprisingly close to the average molecular kinetic energy per degree of freedom per kelvin From these it follows that 1 kilogram kg 8 987551 787 368 1764 1040 6 091102 297 113 866 55 DMCs 1 joule J 1024 6 091102 297 113 866 55 DECs 1 watt W 1 J s 1014 5 599326 049 076 890 895 507 029 35 DECs DnCs 1 newton N 1 J m 2 997924 58 1022 5 599326 049 076 890 895 507 029 35 DECs DlCs 1 pascal Pa 1 N m2 2 694400 241 737 398 953 933 5912 1019 4 731681 297 378 209 131 892 876 988 924 868 114 516 206 15 DECs DlCs 3 1 gray Gy 1 J kg 1 89 875 517 873 681 764 DECs DMCs c2 89 875 517 873 681 764 1 sievert Sv the ionizing radiation dose equivalent to 1 gray of gamma rays Prior to the revision between 1889 and 2019 the family of metric and later SI units relating to mass force and energy were somewhat notoriously defined by the mass of the International Prototype of the Kilogram IPK a specific object stored at the headquarters of the International Bureau of Weights and Measures in Paris meaning that any change to the mass of that object would have resulted in a change to the size of the kilogram and of the many other units whose value at the time depended on that of the kilogram Temperature From 1954 to 2019 the SI temperature scales were defined using the triple point of water and absolute zero The 2019 revision replaced these with an assigned value for the Boltzmann constant k of 1 380649 10 23 J K implying 1 kelvin K 1 380649 10 23 J 2 per degree of freedom 1 380649 10 23 1024 2 6 091102 297 113 866 55 DECs per degree of freedom 1 380649 1 218220 459 422 773 31 DECs per degree of freedom Temperature in degrees Celsius C temperature in kelvins 273 15 1 218220 459 422 773 31 kinetic energy per degree of freedom 377 124274 35 DECs 1 380649 DECs Amount of substance The mole is an extremely large number of elementary entities i e atoms molecules ions etc From 1969 to 2019 this number was 0 012 the mass ratio between the IPK and a carbon 12 atom The 2019 revision simplified this by assigning the Avogadro constant the exact value 6 022140 76 1023 elementary entities per mole thus uniquely among the base units the mole maintained its independence from the caesium standard 1 mole mol 6 022140 76 1023 elementary entities 1 katal kat 1 mol s 6 022140 76 1014 9 192631 77 elementary entities DtCsElectromagnetic units Prior to the revision the ampere was defined as the current needed to produce a force between 2 parallel wires 1 m apart of 0 2 mN per meter The 2019 revision replaced this definition by giving the charge on the electron e the exact value 1 602176 634 10 19 coulombs Somewhat incongruously the coulomb is still considered a derived unit and the ampere a base unit rather than vice versa In any case this convention entailed the following exact relationships between the SI electromagnetic units elementary charge and the caesium 133 hyperfine transition radiation 1 coulomb C 1019 1 602176 634 e 1 ampere or amp A 1 C s 109 1 472821 982 686 006 218 e DnCs 1 volt V 1 J C 1 602176 634 105 6 091102 297 113 866 55 DECs e 1 farad F 1 C V 6 091102 297 113 866 55 1014 2 566969 966 535 569 956 e2 DECs 1 ohm W 1 V A 2 359720 966 701 071 721 258 310 212 10 4 6 091102 297 113 866 55 DECs DnCs e2 2 359720 966 701 071 721 258 310 212 10 4 6 091102 297 113 866 55 h e2 1 siemens S 1 W 6 091102 297 113 866 55 104 2 359720 966 701 071 721 258 310 212 e2 h 1 weber Wb 1 V s 1 602176 634 1015 6 626070 15 DECs DtCs e 1 602176 634 1015 6 626070 15 h e 1 tesla T 1 Wb m2 1 439964 547 058 622 858 327 023 76 1012 5 599326 049 076 890 895 507 029 35 DECs DtCs e DlCs 2 1 439964 547 058 622 858 327 023 76 1012 5 599326 049 076 890 895 507 029 35 E e c DlCs 1 henry H W s 2 359720 966 701 071 721 258 310 212 106 6 626070 15 h DtCs e2Optical units From 1967 to 1979 the SI optical units lumen lux and candela are defined using the Incandescent glow of platinum at its melting point After 1979 the candela was defined as the luminous intensity of a monochromatic visible light source of frequency 540 THz i e 6000 1 02140353 that of the caesium standard and radiant intensity 1 683 watts per steradian This linked the definition of the candela to the caesium standard and until 2019 to the IPK Unlike the units relating to mass energy temperature amount of substance and electromagnetism the optical units were not massively redefined in 2019 though they were indirectly affected since their values depend on that of the watt and hence of the kilogram The frequency used to define the optical units has the parameters Frequency 540 THz Time period 50 27 fs Wavelength 14 9896229 27 mm Photon energy 5 4 1014 Hz 6 626070 15 10 34 J s 3 578077 881 10 19 J luminous efficacy KCD 683 lm W Luminous energy per photon Qv displaystyle Q mathrm v 3 578077 881 10 19 J 683 lm W 2 443827 192 723 10 16 lm s This implies 1 lumen lm 106 2 246520 349 221 536 260 971 Qv displaystyle Q mathrm v DnCs 1 candela cd 1 lm sr 106 2 246520 349 221 536 260 971 Qv displaystyle Q mathrm v DnCs sr 1 Lux lx 1 lm m2 8 987551 787 368 1764 102 1 898410 313 566 852 566 340 456 048 807 087 002 459 Qv displaystyle Q mathrm v DnCs DlCs 2Summary The parameters of the caesium 133 hyperfine transition radiation expressed exactly in SI units are Frequency 9 192 631 770 Hz Time period 1 9 192 631 770 s Wavelength 299 792 458 9 192 631 770 m Photon energy 6 091102 297 113 866 55 10 24 J Photon mass equivalent 6 091102 297 113 866 55 10 40 8 987551 787 368 1764 kg If the seven base units of the SI are expressed explicitly in terms of the SI defining constants they are 1 second 9 192 631 770 DnCs 1 metre 9 192 631 770 299 792 458 c DnCs 1 kilogram 8 987551 787 368 1764 1040 6 091102 297 113 866 55 h DnCs c2 1 ampere 109 1 472821 982 686 006 218 e DnCs 1 kelvin 13 80649 6 091102 297 113 866 55 h DnCs k 1 mole 6 022140 76 1023 elementary entities 1 candela 1011 3 824339 691 519 516 481 631 301 046 05 h DnCs 2KCD sr Ultimately 6 of the 7 base units notably have values that depend on that of DnCs which appears far more often than any of the other defining constants See alsoRubidium standard Nuclear clockReferencesL Essen J V L Parry 1955 An Atomic Standard of Frequency and Time Interval A Caesium Resonator Nature 176 4476 280 282 Bibcode 1955Natur 176 280E doi 10 1038 176280a0 S2CID 4191481 Markowitz W Hall R Essen L Parry J 1958 Frequency of Cesium in Terms of Ephemeris Time Physical Review Letters 1 3 105 Bibcode 1958PhRvL 1 105M doi 10 1103 PhysRevLett 1 105 Comite international des poids et mesures CIPM Proceedings of the Sessions of the 86th Meeting PDF in French and English Paris Bureau International des Poids et Mesures 23 25 Sep 1997 p 229 Archived from the original PDF on 4 December 2020 Retrieved 30 December 2019 Resolution 1 of the 26th CGPM in French and English Paris Bureau International des Poids et Mesures 2018 pp 472 of the official French publication Archived from the original on 2021 02 04 Retrieved 2019 12 29 Second BIPM Metre BIPM Resolution 1 2018 BIPM Kilogram BIPM Kelvin BIPM Mole BIPM Ampere BIPM Candela BIPM This article incorporates public domain material from Federal Standard 1037C General Services Administration Archived from the original on 2022 01 22 in support of MIL STD 188 External linksWikimedia Commons has media related to Caesium clocks